Process Settings Wizard - 2nd Injection Settings dialog

This page of the Process Settings Wizard is used to specify process settings for the second injection unit, which controls Material B for a Co-injection Molding or Thermoplastics Bi-injection Molding process analysis.

To access this dialog, ensure that you have selected either the Co-injection Molding or Thermoplastics Bi-injection Molding process and an analysis sequence that includes Fill or Fill+Pack, click (Home tab > Molding Process Setup panel > Process Settings), and then click Next to navigate to the Process Settings Wizard - 2nd Injection Settings page.

Note: Some of the items listed below may not be available on the current dialog. This is dependent on the mesh type, molding process and analysis sequence selected.

General settings

Delay timer
A means to delay the injection of material B until a specified time following the start of the injection of material A.
No delay
This is the default setting. Material A and material B are injected at the same time.
By time
Enter the time in seconds, following the start of the injection of material A, when you would like to inject material B.
By ram position
Enter where in the cycle the ram should be, before injecting material B.
By injection pressure
Enter the value that the injection pressure should reach, before injecting material B.
Second injection unit options
Click this button to display the advanced options dialog for second injection unit, which controls Material B.