Temperature, mold boundary result

The Temperature, mold boundary result shows the outside surface temperature of the mold, averaged over the cycle.

Using this result

During the Cool analysis, it is assumed that the outside air temperature is 25°C. Therefore, the mold boundary temperature should be evenly distributed. If the mold boundary temperature is not even, then you may need to make the mold bigger or smaller. If the mold boundary result is showing hot regions, then you may need to add more cooling circuits to your design.

Note: The Mold Block Surface layer must be selected in the Layers pane in order to view this result or add this result to an Moldflow Results file (*.mfr).

Things to look for