After you have set the polymer valve gates, you can edit the timings of all the assigned valve gates from a single dialog.
- Click
().
- Select the valve gate timing method in the Show valve gates controlled by drop-down list. All valve gates using that timing method are listed in the table below the drop-down list.
- To edit a timing parameter, click in the relevant table cell and select the required option or enter the new value. To add additional Open At and Close At events, click Add Open/Close Columns at the top right of the dialog.