Editing valve gate timings

After you have set the polymer valve gates, you can edit the timings of all the assigned valve gates from a single dialog.

  1. Click Valve Gate Timing (Boundary Conditions tab > Feed System panel > Valve Gate Timing).
  2. Select the valve gate timing method in the Show valve gates controlled by drop-down list. All valve gates using that timing method are listed in the table below the drop-down list.
  3. To edit a timing parameter, click in the relevant table cell and select the required option or enter the new value. To add additional Open At and Close At events, click Add Open/Close Columns at the top right of the dialog.
  4. Click OK.