This page of the Process Settings Wizard, which can be accessed by clicking ( ), is used to specify the gate location analysis related advanced options for the analysis sequence.
To access this dialog, ensure that you have selected the analysis sequence
Gate Location
, click ( ), then click Advanced options.
When running a Gate Location analysis, the Advanced Gate Locator algorithm uses the options below.
Minimum thickness ratio | Use the Minimum thickness ratio to automatically exclude extremely thin regions from being considered as positions for injection locations. The default value is 0.25 of the part's nominal thickness. If the default value is too low for your part, enter a new Minimum thickness ratio in the Gate Location Advanced Options dialog. Note: The Gate Location analysis using the Advanced Gate Locator algorithm will not produce a Gating Suitability result for areas that are below the Minimum thickness ratio.
|
Maximum design injection pressure | Specifies the maximum injection pressure to be used in the gate location analysis. The gate location algorithm will take this limit into consideration when searching for feasible gate locations.
|
Maximum design clamp force | Specifies the maximum clamp force to be used in the gate location analysis. The gate location algorithm will take this limit into consideration when searching for feasible gate locations.
|