Solver message 312661

Message Text

** ERROR 312661 ** The thermocouple node and target temperature specification for heating control for the rapid heating and cooling channel requires entries since temperature control has been selected.

Explanation

When a thermocouple is used to control the Rapid heating and cooling cycle by turning on the heating medium, in this case steam, a node must be selected where the thermocouple would be located in the mold. This node must be in the mold model, and not in the part or cooling channel. This node must have accurate temperatures assigned to it, indicating when the heating medium should turn on and when it should turn off.

Resolution

Make sure the chosen thermocouple node is located in the mold model, and that correct temperature information is set for this node.