Solver message 221115

Message text

** WARNING 221115 ** The first valve opening time should be zero for an initially open valve gate. The first opening time has been changed to zero for valve gate group %3d.

Explanation

The first opening value of a valve gate will be ignored if the valve gate is specified as being open at the start of injection.

Resolution

Check that the correct initial condition has been specified for the valve gate and set the first opening time to zero.