The interface conductance value quantifies the ability of heat to pass between the insert, or parting plane, and the surrounding mold material. Interface conductance is an optional input for a Cool analysis that can be assigned to a mold insert or parting plane.
- Click
.
- Click on the mold insert or parting surface that you want to assign an interface conductance for.
- Right-click on the highlighted insert or parting surface and select Properties. If the insert or parting surface isn't created yet, click
() and create it.
- In the Interface Conductance box, enter the required value. You can also set the insert material in this dialog.
- Click OK to close the dialog and save your changes.