Solver message 304220

Message text

** WARNING 304220 ** Coincident nodes. Nodes node number and node number have the same coordinates.

Explanation

The input study file for this analysis contains two nodes which have identical coordinates. A coincident node may indicate a problem in the mesh (for example two mesh regions which are not actually connected) which will affect the solution.

Resolution

Examine the two nodes in the GUI. Use Modeling > Query Entities to locate the nodes. Use Mesh > Mesh Tools > Nodal Tools > Merge Nodes to merge any unwanted nodes.