Process Settings Wizard dialog-Fill Settings for Overmolding Stage

This page of the Process Settings Wizard, which can be accessed by clicking Process Settings (Home tab > Molding Process Setup panel > Process Settings), is used to specify the filling phase simulation related process settings for the overmolding (second component) stage of the overmolding analysis sequence.

Note: Some of the items listed below may not be available on the current dialog. This is dependent on the mesh type, molding process and analysis sequence selected.
Material B Allows you to select and/or edit the material used by Controller B in the analysis.
Mold surface temperature The temperature of the mold at the plastic-metal interface, where the plastic touches the mold.
Melt temperature The temperature of the molten plastic, or melt, as it starts to flow into the cavity.
Filling control Specifies the method by which the filling phase of the analysis is controlled.
Velocity/pressure switch-over The criteria by which the molding machine will switch from velocity control to pressure control.
Pack/holding control Specifies the method by which the pressure phase of the molding process is controlled.
Cooling time Specify a cooling time, or have it calculated automatically during the Fill+Pack analysis.
Advanced options... Displays the advanced options for the analysis.
Fiber orientation analysis if fiber material Enables a Fiber orientation analysis if the material includes fiber.