This page of the Process Settings Wizard, which can be accessed by clicking ( ), is used to specify the molding window related process settings for the analysis sequence.
Injection molding machine | Select and edit an injection molding machine to simulate your molding machine during the analysis. You can configure the injection unit, hydraulic unit, and clamping unit. |
Mold temperature range to analyze | Select the range of mold temperatures to be used in the Molding Window analysis. You can specify a temperature range, or have the program calculate it automatically. |
Melt temperature range to analyze | Select the range of melt temperatures to be used in the Molding Window analysis. You can specify a temperature range, or have the program calculate it automatically. |
Injection time range to analyze | Specifies how you want the molding window solver to choose the range of injection times to scan. |
Advanced options... | Displays the advanced options for the analysis. |