** WARNING 301970 ** No results for the temperature distribution in the 3D core were found in the cool interface file. Flow will continue using the average mold temperature distribution as the intial core temperature. In order to get a the core temperature result from Cool re run Cool with the calculate internal mold temperature check box set to on.
The solver has the option of using using the cycle averaged steady state temperature distribution in the core from the Cool analysis as the intial temperature in the 3D core for the Fill+Pack analysis. This option has been set in the flow advanced features option however the solver cannot find the temperature results from the Cool analysis. When the Cool analysis was run the option to generate these results was turned off. The solver will continue using the average mold temperature result from cool as the initial condition.
Re run the Cool anlaysis with the calculate internal mold temperature check box checked.