The Maximum wire sweep index - Wire number: XY Plot result shows the maximum wire sweep index value of each wire in the model.
The Maximum wire sweep index - Wire number: XY Plot result is generated by a 3D Microchip Encapsulation analysis when the selected analysis sequence includes Wire Sweep.
The single maximum value of the wire sweep index predicted for each wire is plotted versus the wire number.
Using this result
Use this information to identify individual wires that undergo the greatest drag force during cavity filling.
Note: In order to calculate the Maximum wire sweep index - Wire number: XY Plot result, the wire sweep calculation must be performed in Autodesk Simulation Moldflow Insight.
Tip: This option is set on the
Microchip Options tab of the
Reactive Molding solver parameters (3D) dialog. Double-click
Process Settings in the Study Tasks pane, or click

() to open the
Process Settings Wizard. Click
Next to display the
Profile Settings page; click
Advanced options; click
Edit in the
Solver parameters area; and click the
Microchip Options tab. Set the
Perform wire sweep/paddle shift simulation in option to
Autodesk Simulation Moldflow Insight.