Solver message 98954

Message text

** WARNING 98954 ** No contact between 1st and 2nd components was detected. Checking the modeling of both components is recommended.

Explanation

For 2-shot Sequential Overmolding, it's very unlikely that the 1st and 2nd components are totally separated. Usually the 2 components are overlapped in some areas.

Resolution

Make sure the separation between the 1st and 2nd components is less than (h1+h2)/2 in areas where the 2 component are in contact, where h1 and h2 are local thickness of 1st and 2nd components, respectively.