Solver message 301435

Message text

** WARNING 301435 ** No value specified for screw diameter. Using default = screw diameter.

Explanation

The value specified for screw diameter in the Process Settings is outside the expected range, meaning that it is either too small or too large. The analysis will use the default value for the selected injection molding machine.

Resolution

  • Set the machine screw diameter in the machine settings.
  • Select a different injection molding machine.
  • If the injection molding machine is from the Autodesk Simulation Moldflow database, contact Technical Support.