The Shear stress, maximum result shows how the shear stress varies with variations in the mold temperature, melt temperature, and injection time.
This result is generated by the Molding Window analysis.
This result, along with several others, are components of the Molding Window quality result.
The default plot shows the predicted maximum shear stress as a function of mold temperature.
To explore the effect of melt temperature and/or injection time on maximum shear stress, right-click on Shear stress, maximum (molding window) in the Study Tasks pane and select Properties.
Using the Explore Solution Space-XY Plot dialog, select a check box to display that variable, and then drag the sliders of the other two to vary the displayed variable with maximum shear stress.