Solver message 306128

Explanation

Extremely high calculated values of air speed through a vent location can cause problems in the analysis.

Resolution

Edit the venting analyis location properties to increase the vent size, or set more venting analysis locations on the model before starting the analysis again.

To change properties of existing venting analysis locations:
  • Right-click on a specific venting analysis location and select Properties to access the Venting analysis location properties dialog.
  • Change the global venting analysis location properties on the Venting Analysis tab of the solver parameters dialog.

To set a new venting analysis location, select Home tab > Molding Process Setup panel > Boundary Conditions > Venting > Venting Locations to begin.