Solver message 98691

Message text

** WARNING 98691 ** The maximum machine clamp force value in the clamping unit properties of the selected injection molding machine is outside the expected range so a default value of %14.3g will be used instead. Check the injection molding machine settings and run the analysis again.

Explanation

The value specified for maximum machine clamp force in the Process Settings Wizard Advanced options is outside the expected range, meaning that it is either too small or too large. The analysis will use the default value for the selected injection molding machine.

Resolution

  • Change the maximum machine clamp force in the process settings.
  • Select a different injection molding machine.
  • If the injection molding machine is from the Autodesk Simulation Moldflow materials database, contact Technical Support.