Mesh aggregation for 3D Warp analysis

The Use mesh aggregation and 2nd-order tetrahedral elements option is selected by default.

  1. Open a 3D model which requires Warp analysis, and make sure an analysis sequence which includes Warp is set.
  2. Click Process SettingsHome tab > Molding Process Setup panel > Process Settings, or double-click the Process Settings icon in the Study Tasks pane. Click Next one or more times until the Warp Settings page appears.
  3. Clear the Use mesh aggregation and 2nd-order tetrahedral elements checkbox, to disable the mesh aggregation option. When the mesh aggregation option is disabled, you can access additional mesh control options.
  4. Click Advanced options to access additional mesh control options.
  5. Click OK to accept the changes, or Cancel to exit without any changes.
  6. Click Finish.