Hot runner (3D) dialog—Runner Surface Properties tab

The Runner Surface Properties tab of the Hot runner (3D) dialog is used to specify the thermal properties of the hot runner.

Dialog elements

Heater is at
The temperature of the heater element can be specified in two ways.
Melt temperature
The properties of the selected material determine the temperature of the heater.
Temperature =
A specified temperature can be defined. When this option is selected, a text box becomes available for entry of the required value.
Heat loss into mold option
The following options are available
Automatic
The specified constant flux value is used. If a heater element is detected, the program defaults to the Use heater element option.
Constant flux
The specified constant flux value is used.
Insulating properties
The specified insulating properties are used to calculate the heat loss. The insulating layer conductance and the air gap can be defined in the dialog accessed from the Edit insulation button.
Use heater element
The properties of the heater element are used.