Enabling the parallel solution

The Number of threads for parallelization option is set to Automatic by default. Other options include Single thread (No parallelization), which means the parallel solution method will not be used, Maximum, or Specify the number of threads to be used for the parallel solution.

  1. Click (Home tab > Molding Process Setup panel > Process Settings) to open the Process Settings Wizard - Cool (FEM) Settings dialog.
  2. Click Cool (FEM) Solver Parameters to open the Cool (FEM) Solver Parameters dialog.
  3. Change the Number of threads for parallelization option from Automatic to your preference.
    Note: The number of threads specified should not exceed the number of physical processors available.
  4. Click Finish.