Solver message 99645

Message text

** ERROR 99645 ** The value for the machine hydraulic response time is zero or negative. Typical value: 0.2 s. Check the injection molding machine settings and run the analysis again.

Explanation

The value for the machine hydraulic response time is zero or negative.

Resolution

  • Specify a machine hydraulic response time in the process settings.
  • Select a different injection molding machine.
  • If the injection molding machine is from the Autodesk Simulation Moldflow database, contact Technical Support.