Solver message 701500

Message text

** WARNING 701500 ** Cannot freeze element %7d

Explanation

Dual Domain and Midplane Cool analysis use analytic formulas to calculate the time to freeze. In this instance the cycle-averaged mold wall temperatures of the element are hotter than the transition temperature of the material, therefore the part is unable to freeze. These elements are either at the base of bosses, or the specified cooling time is too short. If many convergence errors have been given during integration, then the elemental results for these elements could be incorrectly too hot. This could then give rise to this warning as well.

Resolution

Locate the element specified in the message using Modeling > Query Entities. The cycle time can be increased to ensure that the cycle-averaged mold wall temperatures are all below the transition temperature of the material. If there were integration warnings then those warnings should also be attended to.