Note: A venting location can only be set on an overflow well.
Ensure that you have already set an overflow well on the model.
Click (Boundary Conditions tab > Venting panel > Venting Locations). Cross-hairs will appear, allowing you to specify the vent.
Click the cross-hairs on the overflow well section of the model where you want to set the vent. The overflow well entities should be indicated on the model by a green color. After you set the vent, a light blue icon will appear.
Right-click and select Finish Venting Locations.
then click (Save > Save Study) to save your study.
Note: You can update the name of the vent later by right-clicking on the light blue icon and selecting Properties.