The Venting Analysis tab dialog is used to specify input values for a venting analysis, when using a 3D mesh type and an analysis sequence that includes Fill or Fill+Pack using the Coupled 3D Flow solver.
| Venting analysis option | This option determines if a venting analysis will be performed. |
| Vent size | Specify the size of the vent associated with a venting analysis location. |
| Vent exit pressure (Gauge) | Specify the exit pressure of the vent associated with a venting analysis location. |
| Minimum void volume option | Set the minimum volume of entrapped air that will be considered as a void (air trap). |
| Venting analysis locations grouping | Specify whether to allow multiple nodes (venting analysis locations) to be defined as a single air vent. |