Solver message 307022

Message Text

** ERROR 307022 ** There is no initial charge in the compression surface. Please check the model/input data, and run the analysis again.

Explanation

In order to run an injection-compression analysis, both a part and a polymer charge must be modeled and meshed. The elements of the polymer charge mesh must then be assigned the property type "Initial charge (3D)". If you haven't modeled the polymer charge, or if you haven't assigned the correct property type to it, the analysis cannot proceed.

Resolution

Model a polymer charge, if you haven't already done so. If you have a polymer charge present, make sure that it has been meshed, and the mesh elements have been assigned the property type "Initial charge (3D)".