Solver message 1714120

Message text

** WARNING 1714120 ** The CRYSTALLINITY term in the PARALLEL strain model had values which were too LOW in %5.1f%% of part elements (volume fraction). The lower limit has been used for these elements.

Explanation

The calculated crystallization related contribution to the predicted parallel shrinkage within the part exceeded the measured limits obtained under the range of process conditions considered in the shrinkage testing of the material.

Resolution

If the percentage part volume value is high, then the results of the Shrink analysis may not be reliable because the process conditions used in this study are significantly different to those considered in the shrinkage testing.