Solver message 99602

Message text

** ERROR 99602 ** You have selected Velocity/pressure switch-over by pressure control point, however the specified node (%7d) cannot be found. Use the Query Entities tool in the Modeling menu to determine the correct node number, re-enter the pressure control point node in the Process Settings Wizard, then rerun the analysis.

Explanation

The node that was specified for the Velocity/pressure switch-over By pressure control point cannot be found in the model.

Resolution

If necessary, turn on the layer(s) containing the nodes in the model. Select Modeling > Query Entities and click on the node that you want to use as the pressure control point. Note down the displayed node number. Select Analysis > Process Settings Wizard, and click on the Edit settings... button associated with the Velocity/pressure switch-over option. Enter the correct node number in the Pressure Control Point Settings dialog.