Solver message 220020

Message text

** ERROR 220020 ** Velocity/pressure switch-over time cannot be after rescale time.

Explanation

The velocity (filling) control profile has been scaled to match an absolute duration time, however the switch-over from velocity to pressure control (packing) has been specified by a time value which is greater than the filling phase duration. Therefore, switch-over to pressure control cannot occur before the cavity is 100% filled.

Resolution

Select Analysis > Process Settings Wizard and set an earlier Velocity/pressure switch-over time, or a longer velocity profile duration under Filling Control.