The Temperature, mold-insert difference (transient from start-up) result shows the temperature difference between the mold and the mold insert at their interface, at every time iteration throughout the injection molding cycle.
The Temperature, mold-insert difference (transient from start-up) result is calculated using the finite element boundary method (FEM).
The temperature difference is determined by the external heat transfer coefficients (HTC), or the interface conductance, which are user-defined. A lower HTC value represents a greater resistance to heat transfer.
You can use this result to identify whether heat is being extracted sufficiently from the insert. Using the cutting plane tools, you can also examine the temperatures within the mold insert; there should be only a small variation in average temperature. Areas of high average temperature may indicate areas that are poorly cooled. Consider adding cooling channels near these areas.