Solver message 301420

Message text

** WARNING 301420 ** No value specified for maximum injection pressure. Using default = injection pressure value .

Explanation

The value specified for maximum machine injection pressure in the Process Settings is outside the expected range, meaning that it is either too small or too large. The analysis will use the default value for the selected injection molding machine.

Resolution

  • Set the maximum machine injection pressure in the machine settings.
  • Select a different injection molding machine.
  • If the injection molding machine is from the Autodesk Simulation Moldflow database, contact Technical Support.