Solver message 129010

Message text

** ERROR 129010 ** The maximum gas injection pressure is < or = to zero. Enter an appropriate value in the gas pressure or gas volume controller dialog and re-run the analysis.

Explanation

The maximum gas pressure value in the Gas-assisted injection controller dialog for one of the gas entrances is invalid.

Resolution

To view the Gas-assisted injection controller settings of each gas entrance, right-click on the gas entrance symbol and select Properties. Click Edit... in the Gas entrance dialog. If you have selected Gas injection control by Gas volume controller, click Edit controller settings and, if necessary, correct the Maximum gas pressure. If you have selected Gas injection control by Gas pressure controller, click Edit controller settings and, if necessary, correct the Gas pressure values in the Gas pressure vs time table.