The heat transfer effectiveness (HTE) is a required input for a Cool analysis that specifies the heat extraction efficiency of mold surfaces, including cooling circuits (channels), baffles, bubblers, or connectors. An HTE value of 1 indicates that the mold feature only absorbs heat, while an HTE value of 0 indicates that the feature absorbs no heat from the mold.