Distribution is ALWAYS symmetrical with respect to the length of a segment in which distribution is performed. The designations:
L - length of a segment of distribution
s1- initial spacing
Smax - maximum spacing
n = L/2 - spacing module rounded upwards to a whole value
so =s1/2 - position of the first point at the beginning and end of a distribution line.
The set of available CAQUOT spacing values includes: 7, 9, 11, 13, 16, 20, 25, 35, 60 cm
Select distribution type : [Linear / varying Linearly / Arc / Point] <Linear>
Distribution method : [Zone / Module / Caquot] < Caquot>
Direction of projection - viewing a bar [X / Y / Any / Segment] <Y>
Any – Determine direction of viewing a bar
Segment – Select bar segment
Dialog box closing
Start distribution point or [select Line]
End distribution point or [Back]
Initial spacing or [Side / Cover / Back ] <9>
Maximum spacing <35>