Linear distribution (Caquot)

Distribution is ALWAYS symmetrical with respect to the length of a segment in which distribution is performed. The designations:

L - length of a segment of distribution

s1- initial spacing

Smax - maximum spacing

n = L/2 - spacing module rounded upwards to a whole value

so =s1/2 - position of the first point at the beginning and end of a distribution line.

The set of available CAQUOT spacing values includes: 7, 9, 11, 13, 16, 20, 25, 35, 60 cm

Command line

Select distribution type : [Linear / varying Linearly / Arc / Point] <Linear>

Distribution method : [Zone / Module / Caquot] < Caquot>

Direction of projection - viewing a bar [X / Y / Any / Segment] <Y>

   Any – Determine direction of viewing a bar

   Segment – Select bar segment

Dialog box closing

Start distribution point or [select Line]

End distribution point or [Back]

Initial spacing or [Side / Cover / Back ] <9>

Maximum spacing <35>