Save Joint Settings to Library for later use
To avoid setting many parameters every time you create the same connection, it is possible to save preferred configurations in the
Library
.
Every time a joint is created, Advance Steel searches if the same combination of elements section class and size is already in the
Library
. If it finds a match it will apply the settings stored against that entry in the Library. This way you do not have to go through setting many parameters every time you place the joint.
- If there is more than one possible match in the Library for the current joint, the first match from the table is used.
- If no match is found in the Library, a dialog box displays a warning message: "Template values not found. Take defaults of the connection".
Note:
- There is no link between the joint parameters and the
Library
. You may change the settings in the library, without affecting the other already created joints .
- "Copy by template" and "Copy by template, multiple" do not use the joint library; these commands copy the parameters of the joint to be copied.
Tip:
To turn off the message dialog box, change the corresponding default in the
Management tools
:
Defaults
>
General
>
Message box when template values not found
.
Access the Library
You can access the
Library
from the joint properties dialog box,
Library
tab.
The
Library
tab includes a table with columns for every parameter within the joint. Each line of the table corresponds to a saved connection.
Use the Joint Library
To add new settings to the library
- Create the joint and set the parameters according to requirements.
- Display the joint properties and make the necessary settings.
- On the
Library
tab, click Save values.
- A new line is added to the table.
To use a saved set of parameters for a new connection
- Start the
Connection Vault
.
- Select the connection you want to create.
- Select the elements to be connected in the required order and create the connection. The joint properties dialog box appears.
- Select the
Library
tab.
- From the table, click the line corresponding to your choice.
- The parameters are applied immediately.