To Modify Library Symbol Attribute Definitions

Important: Make a backup copy of the library you plan to modify, such as \Users\Public\Documents\Autodesk\Acade {version}\libs\jic1. If the conversion does not give you the results you expect you can restore the symbols, adjust the settings, and then rerun.
  1. Click Schematic tabOther Tools panelSymbol Builder drop-down Modify Symbol Library. Find
  2. Select the folder containing the library symbols you wish to convert and press OK.

    The Symbol Library Attribute Text/Scale Resize dialog box displays. You can change the attribute size based on the AutoCAD Electrical attribute type.

  3. Select the attributes to change. Notice that you can change the attributes for parent/stand-alone symbols separate from the child/contact symbols.
  4. Enter the new value and click Start.

    The first library symbol is immediately opened. Changes are made to the selected attributes. The drawing is saved, and the operation moves on to the next symbol. It continues until each symbol is updated.