To correct profile design criteria violations by entering numeric values
Click the profile. Click Profile tabModify Profile panelGeometry EditorFind.
On the Profile Layout Tools toolbar, click Profile Grid View.
In the Profile Entities vista, click the row that contains the warning symbol in the No. column.
The sub-entity parameters are displayed in the Profile Layout Parameters dialog box.
In the Profile Layout Parameters dialog box, locate the warning symbol in either of the following panels:
Layout Parameters panel — In the Value column, enter a numeric value that meets the value specified in the Constraints column.
Design Checks panel — Notice the design check that has been violated. Modify the profile design to meet the parameters specified in the design check.
To correct profile design criteria violations using grips
In the drawing window, hover the cursor over a warning symbol.
A tooltip displays information about the violation.
Select the profile.
Use the profile grips to modify the profile geometry.
The warning symbol disappears when the sub-entity meets the design criteria.
Note: If a sub-entity violates more than one criteria or design check, only one warning symbol is displayed on the sub-entity. To clear the warning symbol, the sub-entity must be modified to meet all the design criteria.