To correct alignment design criteria violations by entering numeric values
Click the alignment. Click Alignment tabModify panelGeometry EditorFind.
On the Alignment Layout Tools toolbar, click Alignment Grid View.
In the Alignment Entities vista, click the row that contains the warning symbol in the No. column.
The sub-entity parameters are displayed in the Alignment Layout Parameters dialog box.
In the Alignment Layout Parameters dialog box, locate the warning symbol in either of the following panels:
Layout Parameters panel — In the Value column, enter a numeric value that meets the value specified in the Constraints column.
Design Checks panel — Notice that the design check that has been violated. Modify the alignment design to meet the parameters specified in the design check.
To correct alignment design criteria violations using grips
In the drawing window, hover the cursor over a warning symbol.
A tooltip displays information about the violation.
Select the alignment.
Use the alignment grips to modify the alignment geometry.
The warning symbol disappears when the sub-entity meets the design criteria.