Message Text
** ERROR 308308 ** V/P switch-over By %weight reduction value is not specified or not appropriate.
Please check the value and run the analysis again.
Explanation
You have set up to run a Microcellular injection molding analysis, and you have selected to switch from velocity control to pressure control By %weight reduction, but you haven't specified by what percentage you would like the weight of the part to be reduced. Enter a value between 0 and 50%; a typical value might be 10%.
Resolution
Enter, or correct, the
Velocity/pressure switch-over (Microcellular) in the
Process Settings Wizard:
- Click
().
- Confirm the Velocity/pressure switch-over parameter selection, and change it, if appropriate, using the drop-down selection.
- Check the data entry box associated with Velocity/pressure switch-over (Microcellular), and enter a value, or correct the existing value.
- Click Next, if necessary, to progress to the last page of the Process Settings Wizard.
- Click Finish to close the dialog.