Solver message 308234

Message Text

** WARNING 308324 ** Velocity/pressure switch-over by %weight reduction value is not specified. Continuing the analysis with velocity/pressure switch-over by % volume filled of xx% obtained from the volume filled at start foaming value in the old study file.

Explanation

The study you are running was created in a version prior to the 2016 release. The microcellular injection molding workflow has since been streamlined and additional simulation models added, and as a consequence the process settings in your study need to be updated.

The default velocity/pressure switchover is By %weight reduction. You need to either select a different option, or enter a value here. The analysis will continue, using the Volume filled at start of foaming value that you entered in the legacy release.

Resolution

To edit the velocity/pressure switch-over, click (Home tab > Molding Process Setup panel > Process Settings). You can then either
  • enter a value for By %weight reduction
  • change the Velocity/pressure switch-over (Microcellular) control to something different.