Reactive molding analysis sequences

The following analysis sequences are available for the reactive molding process:

This molding process simulation is supported by all mesh types:
Analysis sequence Mesh type
Fill (Compressible) Midplane Dual Domain
Fill + Pack 3D
Fill + Pack (Compressible) Midplane Dual Domain
Flow (Incompressible) Midplane Dual Domain
Fill + Pack + Warp (Compressible) Midplane Dual Domain
Fill + Pack + Warp 3D
Cool (FEM) 3D
Cool (FEM) + Fill + Pack 3D
Cool (FEM) + Fill + Pack + Warp 3D
Runner Balance (Compressible) Midplane Dual Domain
Runner Balance (Incompressible) Midplane Dual Domain
Remember: Flow refers to the analysis sequence, Fill + Pack.
Note: For 3D mesh types, there is no option to select compressible or incompressible, because the analysis run depends on the pvT data entered.

You can also run a Venting analysis (3D only) by selecting the option in the Venting analysis tab of the solver parameters dialog, which can be accessed through the Process Settings Wizard.