Message text
** ERROR 3000405 ** Material change - The material could not be found at the selected database location or the type of the material is not compatible with the study.
Explanation
Error 3000405 will occur under the following conditions:
- The required Material ID cannot be found at the location specified.
- Thermoplastic materials can only be replaced by another thermoplastic material. The same condition applies for Thermoset materials. The Material ID points to a different type of material.
Resolution
Check the Modifier file used by the studymod utility and correct the following where relevant.
- Confirm that the pathway specified by the Location attribute is correct.
- Check that the selected material is in the database and that the correct Material ID has been specified.