This dialog is used when setting up for a rapid heating and cooling analysis, using induction heating as the heat source.
To access this dialog, click on an induction coil element, then click ( ). Select Time as the Induction coil control, then click Specify.
Widget | Explanation |
---|---|
Switch off time | Enter the time, within a cycle, at which the induction coil will be switched off. |