Exporting Midplane data to Abaqus from the user interface

Note: This feature is only available for Midplane models on PC.
  1. Ensure that you are using a Midplane model.
  2. Ensure that you have selected an analysis sequence that includes Fill+Pack.
  3. Click Process Settings (Home tab > Molding Process Setup panel > Process Settings).
  4. If necessary, click Next one or more times to navigate to the Fill+Pack Settings page.
  5. Click Advanced Options. The Fill+Pack Analysis Advanced Options dialog appears.
  6. Click Edit next to the Solver Parameters field. The Thermoplastics injection molding solver parameters (Midplane) dialog appears.
  7. Select the Interface tab and click Abaqus options. The Abaqus Options dialog appears.
  8. Select the appropriate interface combination from the drop-down list.
  9. Click OK.