The Cool Analysis tab of the Solver Parameters dialog is available to optimize cool analysis calculations according to your requirements.
The factors that are taken into consideration and the accuracy imposed on an analysis will impact on the speed and accuracy of an analysis. Parameters available for edit include:
- Method for calculating geometric influence
- The default entry is Ideal
- Mold temperature convergence tolerance
- The default entry is 0.1
- Maximum number of mold temperature iterations
- The default entry is 50
- Include runners in automatic cooling time calculations
- The default entry is no.
- Use aggregated mesh solver
- The default entry is yes.