Specifies advanced settings for creating Iso drawings.
Export Settings
- Create PCF on Iso Creation
- Create piping component files (PCF) when creating Iso drawings.
- Export Tables on Iso Creation
- Create data files from the tables that are created. Tables must exist in the title block to be exported.
- Report Export Format
- Sets the format of the table data file (text or Excel).
Advanced Settings and Overrides
- Ignore Break Points from Model
- Ignore break point markers.
- Ignore Iso Annotations from Model
- Ignore Iso message and location markers.
- Reverse Iso Start and End Points
- Assume the opposite flow direction for the line to reverse sheet order. Flow direction is not a property in the model. An arbitrary (but consistent) flow direction is assumed that you can reverse.
- Override Default North Arrow Direction
- Ignores the North arrow direction specified in the title block.
Drawing Congestion Splitting
- Level of Congestion to Split Iso at
- Specifies a preference for the number of objects allowed in an Iso drawing sheet compared to the number of sheets generated. Setting a High congestion level will result in fewer sheets, with more objects on each sheet.
The Maximum setting will force the iso onto one sheet if possible (this replaces the Force Iso onto One Sheet option from earlier versions).
Override Iso Splitting
- Split Iso when Property Changes
- Changes sheets when any of the specified model property values change.
Override Location
- Offset location
- Adds X and Y values to objects in the isometric drawing. You can enter negative values (for example: -10000).
- Offset rotation
- Rotates objects in the isometric drawing. You can enter negative values (for example: -90). Offset rotation is calculated before offset location.