Exercise 3: Adjusting and Verifying Settings

In this exercise, you will view and adjust several types of survey settings.

Survey user settings are specific to a Windows user login account and affect only the survey features, and not the database or drawing data.

Survey database settings are specific to the survey features of an AutoCAD Civil 3D survey database.

This exercise continues from Exercise 2: Setting the Equipment and Figure Prefix Databases.

Specify user settings

    Note:

    This exercise uses Survey-1.dwg with the modifications you made in the previous exercise.

  1. In Toolspace, on the Survey tab, click .
  2. In the Survey User Settings dialog box, specify the following parameters:
    • MiscellaneousUse External Editor: Yes
    • Network Preview: All Selected
    • Setup Preview: All Selected
    • Figure Preview: All Selected

    Selecting the check boxes enables the previewing of all survey components in the ToolspaceSurvey tab.

  3. Click OK.

Specify survey database settings

  1. In Toolspace, on the Survey tab, in the Survey Databases collection, right-click the Survey 1 database. Click Edit Survey Database Settings.
  2. In the Survey Database Settings dialog box, under Precision, specify the following parameters:
    • Angle: 4
    • Distance: 3
    • Elevation: 3
    • Coordinate: 4
    • Latitude And Longitude: 8

    These precision settings are independent of the Drawing Settings precision settings and affect all aspects of the user interface that displays the survey data.

  3. Under Least Squares Analysis Defaults, specify the following parameters:
    • Network Adjustment Type: 3-Dimensional
    • Confidence Level: 99% confidence
    • Perform Blunder Detection: Yes
    Note:

    The Error Tolerance values specify the acceptable error values for the survey measurement. The values in this collection correspond to the units of measure that are specified in the Units collection.

  4. Click OK.

To continue this tutorial, go to Exercise 4: Setting Survey Styles.