Device Feature Classes

This group contains the device feature classes that make up the electric network. The electric network also includes the Conductor feature class. The Electric_CONN feature class stores flow and connectivity information for the logical topology. Most device feature classes also have predefined label and model feature classes as well. All devices are related to a circuit (FID_CIRCUIT). See also Circuit Feature Class.

Feature class Type Table name and description
Breaker Point geometry

EL_BREAKER. A protection device that opens in an overcurrent condition to protect the circuit. A breaker is usually installed in substations at the start of a circuit.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Bus Bar Point, line, and polygon geometry

EL_BUS_BAR. A heavy conductor used to collect, carry, and distribute electric currents.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Capacitor Point geometry

EL_CAPACITOR. An electric circuit element used to store charge temporarily.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Current Regulator Point geometry

EL_CURRENT_REGULATOR. Maintains the current on the network within a given tolerance.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Elbow Point geometry

EL_ELBOW. A terminator for a conductor before it connects to a device.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Electric_CONN Attribute EL_ELECTRIC_CONN. This table is used internally for logical topology information (connections and flow) for electric networks. Do not modify this table.
Fault Thrower Point geometry

EL_FAULT_THROWER. An earth switch that is closed by local protection equipment on an energized circuit under fault conditions, remotely tripping the circuit-breaker(s) controlling the circuit.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Feeder Point geometry

EL_FEEDER. A device at the start of a circuit.

Related tables: EL_CIRCUIT, EL_STRUCTURE, EL_MANUFACTURER, EL_CURRENT, EL_MATERIAL, EL_VOLTAGE, EL_STATE, EL_PHASE

Fuse Point geometry

EL_FUSE. A protection device that opens to protect the upstream circuit sections from faults occurring downstream from the fuse. The fuse opens when the operating current exceeds the cutout current.

Related tables: EL_CIRCUIT, EL_CONTACT_CONCESSIONAIRE, EL_CONTACT_INSTALLER, EL_CONTACT_MAINTENANCE, EL_CONTACT_OPERATOR, EL_CONTACT_OWNER, EL_LOCATION, EL_STRUCTURE

Generator Point geometry

EL_GENERATOR. Converts mechanical energy into electrical energy.

Related tables: EL_CIRCUIT, EL_CONTACT_CONCESSIONAIRE, EL_CONTACT_INSTALLER, EL_CONTACT_MAINTENANCE, EL_CONTACT_OPERATOR, EL_CONTACT_OWNER, EL_LOCATION, EL_STRUCTURE

Ground Point geometry

EL_GROUND. Grounds electrical equipment to earth.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Head Bolt Outlet Point geometry

EL_HEAD_BOLT_OUTLET. Supplies electric current for vehicle heating in cold weather climates.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Isolator Point geometry

EL_ISOLATOR. Separates a component, circuit, or system from a source of electricity.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Junction Point geometry

EL_JUNCTION. Links two or more conductors.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Light Point geometry

EL_LIGHT. A street light.

Related tables: EL_CIRCUIT, EL_MANUFACTURER, EL_STRUCTURE

Lightning Arrester Point geometry

EL_LIGHTNING_ARRESTER. Protects the electric network from lightning.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Load Tap Changer Point geometry

EL_LOAD_TAP_CHANGER. On-load tap-changing mechanism for power transformers.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Meter Point geometry

EL_METER. Measures the quantity and rate of electricity through a section of line.

Related tables: EL_CIRCUIT, EL_CONTACT_CONCESSIONAIRE, EL_CONTACT_INSTALLER, EL_CONTACT_MAINTENANCE, EL_CONTACT_OPERATOR, EL_CONTACT_OWNER, EL_LOCATION, EL_STRUCTURE

Motor Point geometry

EL_MOTOR. Converts electrical energy into mechanical energy.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Recloser Point geometry

EL_RECLOSER. A protection device that detects downstream faults and interrupts the faulted section.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Regulator Point geometry

EL_REGULATOR. Maintains the current on the network within a given tolerance.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Riser Point geometry

EL_RISER. The connection between underground and overhead networks.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Sectionalizer Point geometry

EL_SECTIONALIZER. A protective device that automatically isolates faulted sections of a circuit. Because it does not have fault-interrupting capability, a sectionalizer is used with a backup device such as a breaker or a recloser.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Service Point Point geometry

EL_SERVICE_POINT. The boundary between the network and the customer. A service point may have many customers associated to it. The symbology of the service point reflects the type of customers fed by the network at that point.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Sleeve Point geometry

EL_SLEEVE. Repairs or connects cable.

Related tables: EL_CIRCUIT, EL_CONTACT_CONCESSIONAIRE, EL_CONTACT_INSTALLER, EL_CONTACT_MAINTENANCE, EL_CONTACT_OPERATOR, EL_CONTACT_OWNER, EL_LOCATION, EL_STRUCTURE

Switch Point geometry

EL_SWITCH. Opens or closes to change the load distribution or the configuration of the network.

Related tables: EL_CIRCUIT, EL_CONTACT_CONCESSIONAIRE, EL_CONTACT_INSTALLER, EL_CONTACT_MAINTENANCE, EL_CONTACT_OPERATOR, EL_CONTACT_OWNER, EL_LOCATION, EL_STRUCTURE

Termination Point geometry

EL_TERMINATION. Terminates a loose end of a conductor.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Transformer Point geometry

EL_TRANSFORMER. Converts the generator's low-voltage electricity to higher voltage levels for transmission to the load center, such as a city or factory.

Related tables: EL_CIRCUIT, EL_STRUCTURE

Way Point geometry

EL_WAY. A switchable point within low voltage switchgear.

A way is a point of isolation on a low voltage network. The circuits that come from a low voltage board in substations are protected by a fuseway. The connection between the low voltage board and transformer is controlled by a linkway.

Related tables: EL_CIRCUIT, EL_STRUCTURE