Depending on various conditions, such as number of observations, over determination, quality of the geodetic network, or desired accuracy you can specify the number of parameters that will be determined for the transformation. Transformation parameters are:
Also you can specify that for each session the transformation parameters will be determined independently, or you can select a session that will be used to determine the parameters, and some or all other sessions will use the same values.
To specify the transformation
Transformation tab Parameter area |
Description |
---|---|
No |
Specifies that the transformation parameter will not be determined for the transformation. |
New |
Specifies that the parameter will be determined, and will be used for the transformation. |
Previous |
Specifies that the value of the previous session will be used for the transformation. For the selected session, the value will not be determined, and the transformation will be calculated using the value of the previous session. The previous session is recognized by the session number. For example, session number 4 is previous to session number 5. |
The default settings specify a Helmert transformation.
To specify an affine transformation, set all parameters to New.
For each parameter, the Transformation Planimetry tab and the Transformation Altimetry tab displays the option, value and standard deviation.