You can control the number of features to store in the Last Used list, the time to pause when inserting ducts and conductors across multiple cross sections, the order of the containers, and feature attributes displayed in the container.
You can specify:
- The number of Last Used features to save per container as you work.
- Whether or not the feature class form should display automatically after you create a new feature.
- The time to pause when inserting ducts or conductors across multiple cross sections. You can set this time to zero to approve all the snap points and insert the ducts or conductors at once.
- The containers to display for each profile and in what order.
- Which attributes are visible in the containers and in what order.
To customize the Electric Explorer
- From the Electric Explorer profile list, select a profile, for example, Underground.
- From the Electric Explorer tool bar, click Show Document Settings.
- In the Document Options dialog box, in the left pane, click Electric Explorer or Electric CE Explorer depending on which module you are using.
- Under Electric Explorer Options, click the General tab. Set any of the following options:
General Tab Option |
Description
|
Last Used Features
|
Specifies the number of features that are shown in the Last Used section of the containers.
|
Feature Creation
|
Specifies the behavior of the application during feature creation. Select Show Form After Create New if you want the form to be opened after feature creation so you can specify attributes.
When you are creating features across multiple snap points, you can increase the speed of the process by specifying the delay between snap points in milliseconds. If you set the value to zero, you see a zoomed out map with all snap points highlighted through the last segment. You can create the duct or conductor in one click.
|
- Click the Profile_Name Feature Containers tab.
Where Profile_Name is the current Electric Explorer profile.
- Under Visible Feature Containers, specify which containers to display in the Electric Explorer. Use the up and down arrows to arrange the order of containers.
Note that when you select features in the Visible Feature Containers list, the list of attributes in the Attribute Visibility/Order list, update appropriately.
- Under Visible Feature Containers, select a feature.
- For the selected feature, under Attribute Visibility/Order, specify the attributes to make available for editing in the container.
- Use the up and down arrows to specify the order of the attributes.
Repeat steps 7, 8, and 9 for each feature container.