Use the Find Fed Devices workflow to find all features that are fed by a particular device. The workflow is designed to trace from the electricity source to any consumer. Start features must be switchable or feeder devices (classes in EL_DEVICE_CLASS with ID_DEVICE_TYPE=SWITCHABLE, PROTECTIVE or FEEDER).
Note: Administrators: The conditions of the find fed devices tracing template must be inactive because they cannot be used in a normal tracing and are activated temporarily during the workflow execution. They appear as invalid conditions. (
Infrastructure Administrator
only allows you to save inactive invalid conditions.) The template itself should also be inactive because it is not used for normal tracing.
- Click Home tab Display panel Generate Graphic.
- Click the Workflow Explorer icon to display the workflows.
- Under Client Workflows, Analysis workflows, click Find Fed Devices. Click Execute.
- Click Select Start Feature. Select the start feature (any protective, feeder switchable device class) in the map.
- Click Select Stop Feature. Select one or more stop features in the map.
Note: Tracing a network without stop features can take a very long time.
- Under Direction To Trace, specify the flow direction to trace.
- Click Include Stop Features to include the stop features in the traces results.
If you clear this checkbox, stop features are not included in the results.
- Click OK to run the workflow.
When the workflow has finished, the fed conductors and devices are selected in the map. All fed features are displayed in a tree view in the Workflows pane. Use the tools at the top of the Workflows pane to open the feature class form, highlight selected features, and zoom to selected features.
- Enter REGEN on the command line to clear the selection in the map.